This ELISA kit can be applied to the in vitro quantitative determination of NA/NE concentrations in serum, plasma and other biological fluids.
This ELISA kit uses Competitive-ELISA as the method. The microtiter plate provided in this kit has been pre-coated with NA/NE. During the reaction, NA/NE in the sample or standard competes with a fixed amount of NA/NE on the solid phase supporter for sites on the Biotinylated Detection Ab specific to NA/NE. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) are added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by adding Stop Solution and the color change is measured spectrophotometrically at a wavelength of 450 nm 2 nm. The concentration of NA/NE in the samples is then determined by comparing the OD of the samples to the standard curve.
Assay type | Competitive |
Format | 96T |
Assay time | 2.5h |
Reactivity | Universal |
Detection Method | Colormetric |
Detection Range | 0.3120 ng/mL |
Sensitivity | 0.19 ng/mL |
Sample Volume | 50L |
Sample Type | Serum, plasma and other biological fluids |
This kit recognizes NA/NE in samples. No significant cross-reactivity or interference was observed.
The unopened kit can be stored at 4 for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions since the kit is received.
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 8 wells 12 strips | -20, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100) | 1 vial, 120 L | |
Concentrated HRP Conjugate (100) | 1 vial, 120 L | -20(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 4(shading light) |
Stop Solution | 1 vial, 10 mL | 4 |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |
Note: All reagent bottle caps must be tightened to prevent evaporation and microbial pollution.
The volume of reagents in partial shipments is a little more than the volume marked on the label, please use in measuring instead of directly pouring.
1.Add 50 L of standard or sample to each well. | |
2.Immediately add 50 L of Biotinylated Detection Ab to each well. | |
3.Incubate for 45 min at 37. Aspirate and wash 3 times. | |
4.Add 100 L of HRP Conjugate to each well. Incubate for 30 min at 37. Aspirate and wash 5 times. | |
5.Add 90 L of Substrate Reagent. Incubate for 15 min at 37. | |
6.Add 50 L of Stop Solution. | |
7.Read the OD at 450 nm immediately. Calculation of the results. |
SR GROUP