This ELISA kit applies to the in vitro quantitative determination of Rat BK concentrations in serum, plasma and other biological fluids.
This ELISA kit uses the Competitive-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with Rat BK. During the reaction, Rat BK in the sample or standard competes with a fixed amount of Rat BK on the solid phase supporter for sites on the Biotinylated Detection Ab specific to Rat BK. Excess conjugate and unbound sample or standard are washed from the plate, and Avidin conjugated to Horseradish Peroxidase (HRP) are added to each microplate well and incubated. Then a TMB substrate solution is added to each well. The enzyme-substrate reaction is terminated by the addition of stop solution and the color change is measured spectrophotometrically at a wavelength of 450 nm 2 nm. The concentration of Rat BK in the samples is then determined by comparing the OD of the samples to the standard curve.
Assay type | Competitive |
Format | 96T |
Assay time | 2.5h |
Reactivity | Rat |
Detection Method | Colormetric |
Detection Range | 1.2580 ng/mL |
Sensitivity | 0.75 ng/mL |
Sample Volume | 50L |
Sample Type | Serum, plasma and other biological fluids |
This kit recognizes Rat BK in samples. No significant cross-reactivity or interference between Rat BK and analogues was observed.
An unopened kit can be stored at 4 for 1 month. If the kit is not used within 1 month, store the items separately according to the following conditions once the kit is received.
Item | Specifications | Storage |
---|---|---|
Micro ELISA Plate(Dismountable) | 8 wells 12 strips | -20, 6 months |
Reference Standard | 2 vials | |
Concentrated Biotinylated Detection Ab (100) | 1 vial, 120 L | |
Concentrated HRP Conjugate (100) | 1 vial, 120 L | -20(shading light), 6 months |
Reference Standard & Sample Diluent | 1 vial, 20 mL | 4, 6 months |
Biotinylated Detection Ab Diluent | 1 vial, 14 mL | |
HRP Conjugate Diluent | 1 vial, 14 mL | |
Concentrated Wash Buffer (25) | 1 vial, 30 mL | |
Substrate Reagent | 1 vial, 10 mL | 4(shading light) |
Stop Solution | 1 vial, 10 mL | 4 |
Plate Sealer | 5 pieces | |
Product Description | 1 copy | |
Certificate of Analysis | 1 copy |